CLGlo™ and CLGlo™-HT
An ATP Bioluminomics™ Assay Platform for Cell Lines and Tumor Cells
Buy CLGlo™ assay kits
Buy CLGlo™-HT assay kits Available as assay kits and
contract research services.
CLGlo™ Assay Applications
- Viability, cell functionality, proliferation / cytotoxicity and cell number assays for virtually any cell line.
- Determine growth kinetics.
- Determine proliferation ability and/potential of engineered cell lines.
- Determine the proliferation/differentiation response/effects of growth factors/cytokines media and other reagents on cell lines.
- High throughput in vitro toxicity testing and screening.
Special CLGlo™-HT Applications
- High throughput in vitro toxicity screening and testing.
- Can be incorporated into drug development ADME/Tox.
- Drug/agent toxicity ranking and comparison with primary stem cells, stem cell lines and ex vivo primary explanted cells.
Advantages of using CLGlo™
- The most sensitive of any assay readouts incorporating proven Bioluminomics™ Technology.
- Instrument-based, quantitative and fully standardized readout procedure.
- Available for adherent or non-adherent cell lines.
- Flexibility to use virtually any in vitro stem cell protocol, reagents and growth factors/cytokines.
- High throughput capability.
- Reliably compare results over time.
- Multiplexing capability to incorporate flow cytometry and other assay readouts for additional information from the same sample.
- Easy to learn, fast to use.
Special Advantages of using CLGlo™-HT
In addition to the advantages of using STEMGlo™, the high throughput in vitro toxicity platform has the following special advantages:
- 96- and 384-well plate availability.
- Rapid turnaround.
- Complete assay calibration, standardization and validation according to regulatory requirements.
Species
Cell Lines Sources
Since cells lines are usually derived from spontaneously or genetically modified normal cells that continuously proliferate, CLGlo™ can be used for virtually any mammalian cell line source. CLGlo™ might also be used for Cell lines derived from non-mammalian species.
Availability
CLGlo™ assays are available for:
- Research with 96-well plates
- In vitro toxicity screening and testing with 96- or 384-well plates
Use
For Research Use Only. Not for clinical diagnostic use.
Major Equipment Required
Plate luminometer or multiparameter plate reader with "glow" luminescence measuring capability.
Kit Contents
- CLGlo™ Base Medium
- ATP standard
- ATP controls
- ATP Enumeration Reagent
- Sterile, 96- or 384-well plates, depending on assay use
- Non-sterile, 96- or 384-well plates, depending on assay use
- Sterile, adhesive foil covers to maintain sterility of unused wells
- Instruction manual
Related Assays

CLFluor™
A Fluorescence Assay Platform for Cell Lines and Tumor Cells
Buy CLFluor™ assay kits
All assays are available as kits
and contract research services.
CLFluor™ Assay Applications
- Viability, cell functionality, proliferation / cytotoxicity and cell number assays for virtually any cell line.
- Determine growth kinetics.
- Determine proliferation ability and/potential of engineered cell lines.
- Determine the proliferation/differentiation response/effects of growth factors/cytokines media and other reagents on cell lines.
Advantages of using CLFluor™
- Uses a fluorescence plate reader or multiparameter plate reader with an excitation filter at 390-400nm and an emission filter at 505nm.
- Non-subjective, instrument-based and quantitative readout procedure.
Available for adherent or non-adherent cells.
- Multiplexes with flow cytometry allowing cells to be detected using other fluorescent labels/markers.
- Multiplexes with luminescence assays.
- Multiplexes with gene expression assays etc for more information from a single sample.
- Flexibility to use virtually any in vitro cell protocol, reagents and growth factors/cytokines.
- High throughput capability.
- Easy to learn, fast to use.
Species
Cell Lines Sources
Since cells lines are usually derived from spontaneously or genetically modified normal cells that continuously proliferate, CLFluor™ can be used for virtually any mammalian cell line source. CLFluor™ might also be used for Cell lines derived from non-mammalian species.
CLFluor™-96 Principle
- Incorporates a customized Promega CellTiter Fluor™ reagent that detects protease activity only in living cells. Fluorescence produced only when the GF-AFC substrate is cleaved by protease activity to produce a fluorescence signal proportional to the number of living cells.
- After culture, just add 100μl of the reagent, mix and measure signal between 30 minutes and 3 hours in a plate reader. Optimal incubation time: 2 hours.
- Uses a plate fluorometer or multiparameter plate reader to measure fluorescence with an excitation filter of 380-400nm and an emission filter of 505nm.
Use
For Research Use Only. Not for clinical diagnostic use.
Major Equipment Required
Fluorescence plate reader or multiparameter plate reader.
Kit Contents
- CLFluor™ Base Medium
- GF-AFC Reagent
- Sterile, 96-well plates, depending on assay use
- Sterile, adhesive foil covers to maintain sterility of unused wells
- Instruction manual
Related Assays

CLLight™
An Absorbance Assay Platform for Cell Lines and Tumor Cells
Buy CLLight™ assay kits
All assays are available as kits
and contract research services.
CLLight™ Assay Applications
- Viability, cell functionality, proliferation / cytotoxicity and cell number assays for virtually any cell line.
- Determine growth kinetics.
- Determine proliferation ability and/potential of engineered cell lines.
- Determine the proliferation/differentiation response/effects of growth factors/cytokines media and other reagents on cell lines.
Advantages of using CLLight™
- Uses a absorbance plate reader or multiparameter plate reader, available in most laboratories.
- Non-subjective, instrument-based and quantitative readout procedure.
Available for adherent or non-adherent stem cells.
- Multiplexes with gene expression assays etc for more information from a single sample.
- Flexibility to use virtually any in vitro stem cell protocol, reagents and growth factors/cytokines.
- High throughput capability.
- Easy to learn, fast to use.
Species
Cell Line Sources
Since cells lines are usually derived from spontaneously or genetically modified normal cells that continuously proliferate, CLLight™ can be used for virtually any mammalian cell line source. CLLight™ might also be used for Cell lines derived from non-mammalian species.
CLLight™-96 Principle
- Incorporates a customized Promega CellTiter 96® AQueous One reagent that measures the amount of soluble formazan by absorbance at 490nm produced by a MTS tetrazolium reduction, colorimetric reaction.
- After culture, just add 20μl of the MTS reagent, mix and read absorbance at 490nm after 1-4 hours in a 96-well plate reader. Plates can be returned to incubator and re-read at a later time for increased sensitivity.
- No solubilization step as in a MTT reaction. Replaces MTT assays.
- Read results between 1-4 hours after addition of MTS reagent. Plates can be returned to incubator and re-read at a later time for increased sensitivity.
Use
For Research Use Only. Not for clinical diagnostic use.
Major Equipment Required
Absorbance plate reader or multiparameter plate reader with a 490nm filter.
Kit Contents
- CLLight™ Base Medium
- MTS Reagent
- Sterile, 96-well plates
- Non-sterile, 96-well plate for background determination
- Sterile, adhesive foil covers to maintain sterility of unused wells
- Instruction manual
Related Assays